       In this article, Yao Lu and Peter B. Harrington explore alternate methods to solve cases of arson. The key part of their study was to find cheaper and more accurate detection methods for ignitable liquids. The second leading cause of deaths and injuries and the leading cause of fires is arson. Throughout the article, Lu and Harrington use gas chromatography along with other methods to find a solution.
            One of the main problems in detecting ignitable chemicals is the fact that chemicals can evaporate, and additional pyrolysis products can be produced that can alter the composition of the chemicals. This results in Lu and Harrington designing a new type of GC-DMS (Gas Chromatograph – Differential mobility Spectrum) that will use a computer statistic system called FuRES (multivariate classification algorithm that uses fuzzy logic to classify data). The computer uses the algorithm along with the data from the GC-DMS to infer what chemicals were used in the fire.
            The next part of the article describes the procedure for the experiment. Lu and Harrington used synthetic carpet from a local store for their experiment. They then applied common chemicals that arsons use.
            The final part of the article describes their findings. They use graphs from the GC-DMS to analyze the results of gasoline, diesel, lighter fuel, and turpentine. In conclusion, their findings were useful for the future experiments involving GC-DMS. Even though this article was written in 2007, the findings will benefit the world today, if they have not already.

Comments

  1. 1. Why did they use carpets to measure the arson compounds?

    2. Why did diesel have fuzzy/unclear peaks? And why did the others not?

    ReplyDelete
  2. 1. Any reason for why the diesel had the least clear peaks?
    2. Which sample fuel, of the 3, had the clearest peaks? Why?

    ReplyDelete
  3. 1. What other functions does the differential mobility spectrometer have for different fields?

    2. How do the properties of compounds analyzed change following arson?

    ReplyDelete
  4. 1. What are the characteristics of a "clear peak"? Describe how clear peaks look and how fuzzy peaks look. (Don't tell me one is fuzzy and the other isn't!)
    2. Were mathematicians on this specific research team or was there collaboration from different sites?

    ReplyDelete
  5. 1. What mechanism in the GC-DMS allows it that increased degree of precision?

    2. What was the degree of error in traditional GC analysis that made GC-DMS analysis more viable?

    ReplyDelete
  6. 1. Did they only use four substances to test?
    2. Why did they choose to use synthetic carpet?

    ReplyDelete
  7. What are the characteristics of a "clear peak"? Describe how clear peaks look and how fuzzy peaks look. (Don't tell me one is fuzzy and the other isn't!)
    http://www.chromatographyonline.com/gc-troubleshooting-petrochemical-analysis
    http://www.chromedia.org/chromedia?waxtrapp=ocgdzGsHiemBpdmBlIEcCvBaC&subNav=bkvfkEsHiemBpdmBlIEcCvBaCfC
    Clear peaks will be symmetrical, non-overlapping, and easy to decipher between other peaks in the chromatogram. Fuzzy peaks can be non-symmetrical where it has a distorted or ‘tailing’ peak or could be ‘fronting’. This is where one side of the peak has a different slope than the other. Fuzzy peaks could also look like multiple peaks have been smeared together (almost like overlapping one another) and the peaks cannot be differentiated.

    Why did they choose to use synthetic carpet?
    https://strathmoredesign.com/carpethowitsmade
    This experiment was trying to find cheaper yet more accurate ways to solve cases of arson and to do so, they would have to replicate the most common conditions found in these cases. With most arson cases occurring in homes using carpet in their experiments is logical so they know what carpet does to the results if any and if it makes detection harder. This is supported by the fact that almost 90% of carpet today is made of a synthetic fiber, whether it be nylon or polyester.

    What was the degree of error in traditional GC analysis that made GC-DMS analysis more viable?
    https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5084691/
    The GC-DMS analysis was most likely more viable because custom software can be made specifically for the identification a scientist is trying to accomplish. The GC-DMS also helps scientists be able to focus on single chemical identification by trying to determine of a target compound is present within more complex sample types (such as accelerants). It wasn’t that a traditional GC analysis had a major degree of error, it was just the fact that the samples used in this experiment had more complex compositions and wasn’t as easily identified with the GC.

    Any reason for why the diesel had the least clear peaks?
    https://core.ac.uk/download/pdf/82505359.pdf
    Diesel had the least clear peaks most likely because of how many compounds are in the make-up of diesel. Scientists devoted to studying accelerants say that it is because of its composition that makes it so very hard to identify.

    ReplyDelete

Post a Comment

Popular posts from this blog

The 411 on Tattoo Ink: dangerous or not?

Title: Sensitive Determination of Volatile Organic Compounds and Aldehydes in Tattoo Inks                      The popularity of a tattoo gone from sub-culture to pop culture in recent years, however, getting a tattoo can potentially put your health at risk. A tattoo is a form of external body modification in which a needle is inserted in the dermis layer in order to transfer the pigments. Tattoo inks are a mixture of organic and metal complex dyes in various solvents; the solvents with ethyl alcohol are more commonly used as the alcohol increases the skin’s permeability but also carries more hazardous materials into the blood. Despite the high numbers of tattooed individuals, there has been no study until now of the harmful solvents and impurities contained in tattoo products.              This study used gas chromatography to develop analytical methods pertaining t...

Preserving Prehistory

A Prehistoric Egyptian Mummy: Evidence for an ‘Embalming Recipe’ and the Evolution of Early Formative Funerary Treatments When one mentions the word ‘mummy,’ Egyptian pharaohs, massive pyramids, lavish burial tombs, and an equally lavish embalming process probably come to mind. These funerary rituals were thought to have begun c. 2500 BCE. However, a recent analysis of the prehistoric Turin mummy shows that rudimentary preparations were made before then. This mummy was the perfect specimen for testing because there was no record of any preservation measures employed after the body had been discovered, which is not true for many other mummies from this period (c. 3600 BCE). Scientists took the opportunity to take textile and tissue samples and perform a battery of tests to determine many things about the life and death of the Turin mummy, but most notably, when  three textile samples from different parts of the mummy were analyzed, gas chromatography showed remnants of plant oil ...

Bad Biogas

Establishment of analysis method for methane detection by gas chromatography An analysis of methane levels in biogas determined whether the levels detected by gas chromatography in the process of food waste fermentation were safe. As methane has greenhouse effects twenty-five times stronger than those of carbon, the analysis is vital to determine the safety of basic food fermentation. First, a sample of biogas was collected from a digestion reactor. After analyzing this substance, only one peak that belonged to methane appeared in the chromatogram as the only other substance was air. According to a table created by the researchers, methane content rose slightly to 12.75% in the initial fermentation phase before shooting to 63.03% in the next phase and settling to 50.76% in the last phase. Since the working curve range unfortunately only went up to 44%, the method of collection used was not acceptable for determining methane levels in biogas.       ...